Follow

How do I use/clean/charge my SOURCE nail XL - Signature Kit (2017)?

How to Use

How to use as a Portable eNail

How to Fill Your Bubbler

  1. Remove the glass bubbler from the attachment (gently pull from the attachment).
  2. Take apart the 2-Piece bubbler.
  3. Pour 1/4 oz. of water into the bottom piece, or until the bubbler is less than 1/4 full.
  4. If some water drops to the bottom chamber of the bubbler, that's ok, but you can tip forward slowly to let the excess water drip down.

How to Prep and Power On

SOURCE_volt_Max_battery_front_.jpg

  1. Attach the SOURCE nail XL attachment to your SOURCE volt Max battery.
  2. With the glass bubbler removed and screw your desired SOURCE nail atomizer clockwise unto the SOURCE nail XL attachment.
  3. Replace the glass bubbler after it's filled with water.
  4. Press the Power Button on your SOURCE volt Max battery sequentially 5 times to turn on.

Using your SOURCE volt Max Battery in Temp Control Mode

Using your Battery in Wattage Mode

  1. With your battery in Wattage Mode, use the Left Button or Right Button to increase or decrease your wattage. 
  2. Use the following Wattage settings depending on the SOURCE nail atomizer type:
    1. 4 Series SOURCE nail (10mm) Titanium: 20w - 28w
    2. 4 Series SOURCE nail (10mm) Ceramic: 24w - 28w
    3. 4 Series SOURCE nail (10mm) Quartz: 15w - 17w
  3. Once you have selected your desired wattage, you are ready to use your eRig!

Using Your eRig

  1. With your desired temperature or wattage selected, use the included Quartz Carb Cap & Dabber to pick up the material you want to vaporizer. 
  2. Press and hold the Power Button on your battery to start heating up your nail. The SOURCE volt Max has a 15 seconds cut off time, we recommend letting your nail cycle between 7-10 seconds to reach optimum temperatures. 
  3. Place your lips on the mouthpiece of the bubbler, press and hold the Power Button, slowly lower your material into the SOURCE nail atomizer Bucket, and inhale softly.
  4. Once all of the material from your Quartz Carb Cap & Dabber has been placed on the atomizer, flip unto the Quartz Carb Cap and cover the top of the glass bubbler to increase vapor strength and density.
  5. Release Power Button when all material has vaporized.
  6. Repeat Steps 1-5 until completely satisfied. 

How to use with a Water Pipe:

Watch a video on how to connect to your Water Pipe

  1. Take apart the bubbler, and connect the Bottom piece upside down on your SOURCE nail XL attachment in comparison to normal use.
  2. Connect the Bottom piece to your favorite 18mm water pipe!

How to use as a Vape Pen

How to Prep and Power On

  1. Attach the SOURCE nail XL globe to your SOURCE volt Max battery.
  2. Remove the Glass Globe and screw your desired SOURCE nail atomizer clockwise unto the SOURCE nail XL Glass Globe attachment.
  3. Fill your SOURCE nail atomizer with the material you'd like to vaporize (we recommend .2g max).
  4. Replace your glass globe.
  5. Press the Power Button on your SOURCE volt Max battery sequentially 5 times to turn on.

Using Your Vape Pen

  1. Place your lips on the mouthpiece of the glass globe, cover the carb hole on the glass globe with your finger, press and hold the Power Button, and inhale softly
  2. Cover the carb hole on the glass globe with your finger.
  3. Press and hold the Power Button and inhale softly.
  4. Release your finger from the carb hole to increase strength and vapor density.
  5. Release Power Button when all material has vaporized.
  6. Repeat Steps 1-5 until completely satisfied.

How to Clean

Watch a video on how to Clean your SOURCE nail XL

How to clean your SOURCE nail XL glass

  • Bubbler
    1. Take apart your 2-Piece bubbler.
    2. Soak both pieces in 91% isopropyl alcohol inside a container overnight.
    3. Once the inside of the glass is clean, pour water into the mouthpiece until all of the alcohol has be washed off.
  • Globe
    1. Soak the globe into a container full of 91% isopropyl alcohol, until most material comes off.
    2. Once the glass is mostly clean, remove from a container and gently use a soft cloth to clean and dry the globe.

How to clean your SOURCE nail atomizers

  1. Unscrew the Ring Cap of the SOURCE nail atomizer by holding the atomizer body and twisting the ring counter-clockwise until it comes off.
  2. Gently remove the Bucket inside (Titanium, Ceramic, or Quartz) and submerge both the Bucket and the Ring Cap into a container full of 91% isopropyl alcohol until clean.
  3. Once the Bucket and Ring Cap are clean, use soft cloth to dry the Bucket and Ring Cap while finishing cleaning any remain of the material.
  4. If the outside of the atomizer body needs to be cleaned, use the soft cloth and spot clean with 91% isopropyl alcohol.
  5. Once the Bucket and Ring Cap have dried, gently place back into the atomizer body (make sure to not press down hard!), and screw the Ring Cap clockwise until closed.

How to Charge

  1. Plug in a micro USB cable to the front of the SOURCE volt Max.
  2. Plug your cable into a wall charger.
  3. Your battery screen will read charging.
  4. Your screen will go blank once fully charged (2-3 hours).
Was this article helpful?
1 out of 1 found this helpful
Have more questions? Submit a request

0 Comments

Please sign in to leave a comment.